Closed
Posted
Paid on delivery
I need a full-scope CFD study on my new data-centre layout to confirm that the proposed cooling architecture works as intended. The analysis must cover cooling efficiency, airflow distribution and overall thermal performance so I can be certain we meet ASHRAE thermal compliance before construction moves forward. Your model should capture the entire white space: raised-floor plenum, cold and hot aisles, racks, CRAC/CRAH units and ceiling return path. Once meshed and solved (ANSYS Fluent, 6SigmaDCX, OpenFOAM or comparable software are all acceptable), I will rely on your results to: • Validate airflow paths and pressure balance • Identify and quantify any hotspots or recirculation zones • Confirm that supply/return temperatures keep equipment within the allowable range under peak load Deliverables 1. Editable CFD model with all boundary conditions and material properties 2. A concise report (PDF) including methodology, key plots, temperature maps, velocity vectors and compliance statement against ASHRAE TC 9.9 limits 3. Executive summary with actionable design tweaks if issues are found 4. Native images/animations for stakeholder presentations Please outline your typical workflow, software version and an estimated timeline in your proposal so I can slot the review sessions into our design programme.
Project ID: 40418286
28 proposals
Remote project
Active 7 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
28 freelancers are bidding on average $512 USD for this job

Having spent over 7 years in the field of Mechanical Engineering, I have developed a deep understanding of what it takes to plan and optimize complex systems such as data centers. My extensive experience with CAD modeling and engineering analysis would be instrumental in creating a detailed CFD model that accurately reflects your proposed data-center layout. Proficient in SolidWorks, Fusion 360, and other CAD tools, I would ensure all boundary conditions and material properties are accurately represented in the model. With strong expertise in finite-element analysis, I am well-versed with ANSYS Fluent and OpenFOAM - both software platforms that align embedded within your workflow.
$250 USD in 1 day
8.6
8.6

Hi, I have done exactly the same project on ANSYS Fluent. I will share screenshots of sample results on the chat. As I can see from the image files attached, we can create the solid domain for the racks and cooling equipment and the fluid domain for the air flow inside the room. I have a CFD expertise using ANSYS Fluent for more than 10 years with thermal engineering master's degree. With my experience and my high computing workstation, I believe I can deliver quality work in time. I look forward to hearing back from you. Best regards, Saleamlak A.
$500 USD in 4 days
7.5
7.5

I am an experienced engineer specializing in ANSYS simulations, offering advanced computational modeling and analysis services to support design validation, optimization, and failure prevention. Using ANSYS Workbench, Mechanical, and Fluent, I can deliver accurate results through structural, thermal, and fluid flow studies, vibration analysis, and failure prediction. Specialized in; 1) 3D model setup and meshing in ANSYS 2) Static structural and thermal analysis 3) CFD simulation for fluid flow and heat transfer 4) Modal and harmonic vibration analysis 5) Fatigue and failure evaluation 6) Optimization and design improvement recommendations 7) Comprehensive technical report with results and conclusions
$250 USD in 3 days
6.4
6.4

Hi there, I would be happy to assist with your data center CFD analysis. With expertise in thermal management, airflow simulation, and ANSYS/OpenFOAM-based CFD, I can deliver a reliable study to validate your cooling design and ensure compliance with industry standards. Approach: Develop full 3D CFD model including racks, CRAC/CRAH units, raised floor plenum, and return paths Perform steady-state simulations to evaluate airflow distribution, pressure balance, and cooling efficiency � Freelancer Identify hotspots, recirculation zones, and thermal non-uniformity affecting equipment reliability � CFD Freelancing Validate temperature compliance with ASHRAE TC 9.9 guidelines under peak load conditions � Freelancer Optimize layout and cooling strategy with actionable recommendations Deliverables: Editable CFD model with boundary conditions and material properties Detailed report with temperature contours, velocity vectors, and airflow analysis Executive summary with design improvements High-quality visuals/animations for presentations Timeline: To be determined after discussing project scope. Budget: Open to negotiation based on complexity. Looking forward to collaborating on your data center optimization project. Let’s connect to discuss further. Best regards, Arati M.
$500 USD in 7 days
6.4
6.4

Hello, I can send you example of my CFD for data centrs which I have done using ANSYS Fluent. I have intel i9 16 cores, 48 Gb RAM. I will set up model, run CFD & Thermal simulation, show thermal plots, velocity plots, dead zone with zero velocity. Where the maximum temp areas located and etc. Please feel free to contact me and ask me additional questions
$500 USD in 7 days
6.2
6.2

Hi, I’m a multidisciplinary engineer focused on design + analysis, delivering production ready CAD and simulation-backed solutions. I work across mechanical and architectural scopes, with clear drawings, practical detailing, and fast communication. Feel free to check my profile for similar projects ,happy to review your scope and suggest the best next steps. G. Zaralı
$750 USD in 4 days
6.3
6.3

804.73 m² hall, 11 CRACs at 140.5 kW each, 12 additional racks at 150 kW — the real question is whether those new racks on the right perimeter survive when you lose one or two cooling units. That's where most data centre layouts fail, and that's where my analysis focuses first. Full white-space CFD model in ANSYS Fluent: plenum, perforated tiles, rack heat loads, CRAC airflow, ceiling return. All three scenarios — normal, N+1, N+2 — simulated against ASHRAE TC 9.9 A1 limits with 158 CFM minimum per rack validated. Temperature maps, velocity vectors, compliance statement, and actionable design tweaks if hotspots appear. Editable model plus presentation-ready animations delivered. What's the plenum depth? That's the first number I need to get the underfloor pressure distribution right.
$500 USD in 7 days
5.7
5.7

With my unique blend of skills in professional writing, data analysis, and technical comprehension, I am confident that I can deliver an exceptional CFD analysis for your data centre. I understand the critical nature of your project and the need to ensure it adheres to ASHRAE thermal compliance standards. My approach to business writing is rooted in research and attention to detail, which will be invaluable in producing precise and comprehensive reports that outline methodology plots, temperature maps, velocity vectors, and actionable design tweaks if necessary. Moreover, having worked on several CFD projects before using tools such as ANSYS Fluent and OpenFOAM amongst others, I possess the expertise required to create a highly detailed and editable CFD model that accurately represents your data centre layout. My commitment to delivering clear and persuasive narratives will ensure that not only will the report contain ample technical data for stakeholder understanding but also concise executive summaries for easy decision-making. In terms of timeline, I understand the importance of time management in this project. I assure you of meeting all deadlines without compromising quality.
$250 USD in 7 days
5.6
5.6

Hi, I am interested in this project. I have wide experience in Raised Floor Data Center Thermal Performance Analysis over my 11 years of CFD Engineer experience . I have done more than 20 Data center thermal analysis recently, please refer to my portfolio for a sample and I can show other Non-NDA projects over chat. For this project, Requested 3 scenarios for 804m² Raised Floor Data Center, including CFD model, Report, Plots and summary. So my work process will be, Work Process: 1. Detailed Discussion: Consult with the client to gather inputs and clarify requirements. 2. 3D Modeling: Create the model and obtain client verification/approval. 3. Meshing: Perform meshing and a mesh independence study to ensure accuracy. 4. Simulation: Run the CFD simulations for one scenario first and then other two scenarios. 5. Results & Optimization: Discuss findings and potential improvements with the client. 6. Final Documentation: Deliver the comprehensive report, plots, and summary. Software: Ansys V2025 / V2026 Timeline: Once all details received, 3d modelling with verification/approval: 6days mesh and independence study: 5 days Simulation: 5 days (for first scenario) and 3 days (for next scenarios) Results: 1.5days. The 700 USD is for above Three simulation runs only. After each improvement simulations will cost 300USD. Please feel free to contact me if you have any questions regarding this process. Best regards, Aravindhan S
$700 USD in 25 days
5.5
5.5

As a software engineer with over 5 years of experience, I am confident in my ability to model and solve complex problems like the one you have presented. My proficiency with ANSYS Fluent, 6SigmaDCX, OpenFOAM, and comparable software will allow me to generate an editable CFD model that captures your intended cooling architecture. Additionally, my knowledge of the ASHRAE thermal compliance standards will ensure that all deliverables are compliant with industry regulations. Throughout my career, I have excelled at delivering concise yet comprehensive reports which will be vital for this project. My experience in technical writing allows me to present data and complex information in a format that is easy to understand. I commit to providing you not just with temperature maps and velocity vectors but also an actionable design tweak summary if any issues are found. Driving efficiency through system optimization is one of my major strengths. Having worked extensively with network configurations and Cisco technologies, I understand the importance of airflow paths and pressure balance in maintaining optimal performance. My team-oriented approach ensures seamless collaboration between stakeholders, making it easy for me to slot review sessions effectively into your design programme without delays. Working on your CFD analysis would be an exciting project for me as it combines several of my key areas of expertise: simulations, software development, and technical writing.
$633.33 USD in 2 days
4.8
4.8

Are you looking for a reliable CFD validation of your data-centre cooling design that clearly proves ASHRAE compliance and highlights any airflow or thermal risks before construction? I’m a Mechanical Design & Simulation Engineer with 5+ years of experience in HVAC analysis, airflow modeling, and thermal validation. I’ve worked on airflow optimization and temperature control studies where system reliability and hotspot prevention are critical. Approach • Build full 3D CFD model: raised floor plenum, racks, CRAC/CRAH units, hot/cold aisles, ceiling return • Apply realistic boundary conditions: heat loads, airflow rates, perforated tiles, and leakage assumptions • Solve for airflow distribution, pressure balance, and temperature fields • Identify hotspots, recirculation zones, and inefficiencies • Validate results against ASHRAE TC 9.9 recommended ranges Deliverables • Editable CFD model with all setup conditions • Detailed PDF report (methodology, contours, velocity vectors, temperature maps) • Executive summary with design recommendations • High-quality visuals/animations for presentation Best regards, Hasan
$250 USD in 3 days
3.7
3.7

Hello, I am a CFD Engineer with experience in data-center cooling simulations, including both air-cooled and liquid-cooled systems. I previously worked on thermal analysis for liquid-cooled data centers at tank and ship levels, and I also have research experience in high-density GPU cold-plates. For this project, I will develop a full CFD model including the raised-floor plenum, CRAC/CRAH units, perforated tiles, server racks, cold/hot aisles and ceiling return path. The racks will be modeled as porous thermal zones with distributed heat loads, while perforated tiles will be represented using porous pressure-loss, and the CRAC units will be represented as inlet and outlet patches( detailed modeling of its components could also be included if needed) The assessment will include airflow distribution validation, hotspot and recirculation zones if exist, and cooling-effectiveness assessment using the RCI metric according to ASHRAE TC 9.9 guidelines. Estimated timeline: approximately 2 weeks depending on CAD quality and level of detail. Software: Ansys Before proceeding, I would like to confirm whether 3D CAD geometry is available or only 2D drawings. I also have a few technical questions regarding the system specifications provided in the attachment, which we can discuss further once connected. I would be happy to discuss the project further and share examples of similar CFD and thermal-analysis work I have completed previously. Regards, Walid Badawy
$750 USD in 7 days
3.1
3.1

I can deliver a full-scope CFD study of your entire white space (raised-floor plenum, cold/hot aisles, racks, CRAC/CRAH units and ceiling return path) to validate airflow paths/pressure balance, quantify hotspots/recirculation, and confirm ASHRAE TC 9.9 intake-temperature compliance under peak load. From your drawings: hall area ~804.73 m², 11 existing cooling units (140.5 kW each, 7900 L/s per unit) and 12 additional racks highlighted in red; 3 required cases: All units ON, N+1 (1 unit unavailable), N+2 (2 units unavailable). Key clarification before setup (potential inconsistency): 12 racks × 150 kW = 1800 kW, which conflicts with the mentioned “1100 kW original capacity”; also “75 L/s per rack” appears too low for 150 kW/rack. I will lock assumptions only after confirming rack loads/airflow units, supply temps, tile free area/ΔP curves, and leakage paths. Software: OpenFOAM (open-source). Deliverables: editable case folder (mesh+BCs+materials), concise PDF report with plots/maps/vectors + compliance statement, executive summary with design tweaks, and presentation-ready images/animations. Timeline :3 weeks calendar including 2–3 review sessions and final deliverables.
$500 USD in 21 days
2.0
2.0

Hello I can deliver a full CFD analysis of your data center, covering airflow distribution, cooling efficiency, and thermal performance in line with ASHRAE TC 9.9 requirements. My workflow includes geometry setup, meshing, simulation, and post-processing to identify hotspots, airflow issues, and optimization opportunities. Deliverables include an editable model, a concise report with key results and compliance check, an executive summary with recommendations, and high-quality visuals/animations. You can also review my experience and past projects on my profile. Best regards, Marzak
$700 USD in 7 days
1.2
1.2

Hi, I specialize in data centre CFD and can validate your cooling design before build. I will simulate the full environment (plenum, racks, CRAC/CRAH, aisles, return path) using ANSYS Fluent or 6SigmaDCX to: • Verify airflow balance and pressure distribution • Detect hotspots and recirculation zones • Ensure temperatures meet ASHRAE TC 9.9 limits You’ll receive: • Editable CFD model • Clear report with temperature/velocity plots • Compliance confirmation • Actionable design improvements • Visuals for stakeholder presentations Timeline: ~7–12 days. I focus on practical insights—not just simulation—so you can move forward with confidence.
$500 USD in 7 days
0.0
0.0

Hi, As an Astronautical Engineer with a professional background in high-fidelity fluid dynamics and structural reliability, I am prepared to deliver a comprehensive CFD study for your data center cooling architecture. Why My Engineering Fits This Scope - I specialize in the deterministic modeling of high-gradient fluid environments. I will model your entire "white space"—from the raised-floor plenum to the ceiling return path—to ensure absolute pressure balance and validate that your airflow paths meet the intended cooling logic. - Drawing on my experience with species-transport and thermal management, I will audit your supply/return temperatures against the specific ASHRAE TC 9.9 thermal envelopes. - Using ANSYS Fluent, I will generate high-resolution velocity vectors and temperature maps, along with native animations for your stakeholder presentations, ensuring the technical data is both actionable and visually compelling. Workflow - Importing your layout and defining boundary conditions for CRAC units (flow rate/setpoints) and rack heat loads. - Building a refined mesh in ANSYS Fluent (Version 2025 R1 or 2026 R1), utilizing SST k-omega or Realizable k-epsilon models to capture turbulent mixing accurately. - Running the simulation at peak load to ensure the thermal architecture sustains the required air-delivery temperatures. - Compiling the PDF report, compliance statement, and stakeholder visuals. Best regards, Batuhan Akkova
$550 USD in 8 days
0.0
0.0

I reviewed your requirement and this is closer to a full data-centre airflow validation than a standard CFD task. One thing I’ve seen repeatedly most simulations look correct visually, but fail to capture pressure balance across the raised floor, perforated tiles and rack intake - which is where hotspots and recirculation actually originate. Before suggesting an approach, I want to clarify a couple of technical points: • Are rack heat loads fixed or load-dependent? • How are perforated tiles being modeled currently? • Is containment part of the design or open aisle? If you’re open to it, I can outline a structured approach to ensure the results are actually usable for ASHRAE compliance, not just visual outputs. Happy to discuss.
$300 USD in 7 days
4.2
4.2

Hello, I have solid experience in data center CFD analysis using Reality DC (formerly 6SigmaDCX) and ANSYS. The simulation will be performed using Reality DC, ensuring accurate airflow and thermal performance validation aligned with ASHRAE guidelines. The CFD model will be developed from scratch based on the provided data, with full attention to detail to ensure high-quality and reliable results. The proposed price covers one full simulation based on the current data center layout. Any changes in equipment, layout, or additional scenarios may affect the cost and timeline. Best regards, Younan Kedees
$700 USD in 10 days
0.0
0.0

Full CFD study for your data centre using ANSYS Fluent/OpenFOAM: modelling complete white space, airflow, pressure balance, hotspots, and ASHRAE TC 9.9 compliance. Deliverables include editable model, detailed report, visuals, and design recommendations. Timeline: ~2–4 weeks.
$700 USD in 10 days
0.0
0.0

I am an aerospace engineer with strong CFD experience, and I’ve worked on airflow and thermal problems where distribution and recirculation directly affect performance, which is very similar to data centre cooling. Here is how I will approach your case: • Build the full domain including raised floor, racks, CRAC units, and return paths • Apply realistic boundary conditions based on your cooling units and rack loads • Run all three scenarios, normal, N+1, and N+2 failure • Analyze airflow distribution, pressure balance, and temperature fields • Identify hotspots, bypass flow, and recirculation zones You will get: • Complete CFD model ready to rerun and modify • Temperature maps, velocity vectors, and airflow distribution plots • Clear validation against ASHRAE limits • Short report with direct recommendations to fix any weak zones • Visual outputs for stakeholder presentation My focus is not just running the simulation, but making sure the results actually help you decide if the design works or needs adjustment. If you share full CAD and operating conditions, I can start immediately and outline the setup before solving.
$750 USD in 7 days
0.0
0.0

Hyderabad, India
Payment method verified
Member since May 19, 2024
$250-750 USD
min $100000 USD
$10-60 USD
$500-550 USD
$8-15 USD / hour
$10-30 USD
₹600-1500 INR
₹12500-37500 INR
₹2000-3500 INR
$30-250 USD
$250-750 AUD
$250-750 USD
$10-30 USD
₹12500-37500 INR
€12-18 EUR / hour
$15-25 USD / hour
₹700-900 INR
$30-250 USD
₹100-400 INR / hour
$15-25 USD / hour
₹1500-12500 INR