
Closed
Posted
Paid on delivery
Delta PLC Programmer Required – Modbus RTU RS485 Machine Counter We require an experienced Delta PLC programmer for our factory production-counting system. PLC: Delta DVP14SS211R (SS2 Series) Communication: Modbus RTU RS485 Master: Dell Linux server using Python PyModbus 3.15 Requirements 1. Configure Modbus RTU slave communication at 9600 baud, 8N1, slave ID 10. 2. All 8 digital inputs (X0–X7) must function as independent production counters. 3. Each machine produces approximately 15,000 pulses per day. 4. Use independent 32-bit counters capable of handling millions of counts without overflow. 5. Each input must support individually adjustable debounce and pulse lockout from 100–2000 milliseconds, controlled through Modbus registers. 6. Preserve all counter values during power failures. 7. Allow Dell to read and reset each counter independently through Modbus. 8. Allow Dell to write and read the active Work Order ID, target quantity and status for each machine. 9. Preserve work-order information after power failures. 10. Support PLC relay output control through Modbus, subject to hardware safety interlocks. 11. Ensure reliable operation during continuous 24×7 factory use. System Architecture PLC: Pulse counting, configurable filtering, work-order data storage and basic output control. Dell Server: All work-order management, production calculations, scheduling, reporting and database logic. No work-order business logic should be implemented inside the PLC. Deliverables * Complete editable PLC program * Modbus register mapping for all 8 inputs * Individual debounce and pulse-lockout configuration * Counter and work-order data retention testing * Successful Modbus communication with Dell * Power-failure and communication-recovery testing * Remote installation support The solution must be suitable for continuous industrial production counting.
Project ID: 40793155
37 proposals
Remote project
Active 14 hours ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
37 freelancers are bidding on average ₹8,182 INR for this job

Industrial PLC programming, Modbus and RS485 communication are central to my automation work, making this Delta DVP14SS211R production-counter system a strong match for my expertise. I develop PLC solutions for factory automation and work with Modbus, RS232, RS485, TCP/IP, Ethernet/IP, CC-Link and Profinet communications. My background includes PLC programming, control-panel design, commissioning and final functional testing, along with troubleshooting wiring, electrical and electronics-related issues in the field. I can provide an editable PLC program supporting the eight independent inputs, configurable filtering, retained counter and work-order data, Modbus read/write access, and controlled relay outputs while keeping business logic on the Dell server. My commissioning experience also aligns with communication recovery, power-failure retention and continuous-production testing. I am ready to contribute a reliable, maintainable automation solution and provide remote installation and testing support for your factory system.
₹7,000 INR in 7 days
6.5
6.5

Hello sir I'm PLC programmer with 10 years of experience in the automation field I have good experience with delta PLC and I do alot of jobs using it I have good experience with wplsoft or ispoft software I also have good experience with Industiral communication and modbus Please contact me for more detailes I hope we can work together Best regards
₹12,500 INR in 7 days
5.6
5.6

Hi there, I am an automation specialist who master PLC programming for many brands including Delta controllers. I highly experienced in Modbus RTU and TCP to interface PLC-to-PLC and PLC-to third party devices and PC as well. please see dozens of completed projects with excellent clients feedback as well Regards Yasser
₹12,500 INR in 7 days
6.3
6.3

The real risk here isn't the counting, it's the reset. If Dell reads a 32-bit counter and then sends a reset as two separate Modbus RTU transactions, any pulse on X0-X7 between them is silently lost, and that drift adds up over 24x7 production. Quick questions - are the inputs dry contacts or NPN/P
₹6,300 INR in 3 days
5.5
5.5

I map all 8 inputs as 32-bit counters with per-register debounce and lockout, Modbus registers for work order ID and target, and retain values across power loss. I can start today.
₹7,000 INR in 7 days
4.9
4.9

Hello, I have considerable experience with DELTA DVP series PLC, RS485Modbus programming. I have done medium size machine control using delta PLC, DLTA HMI etc. I will give
₹8,000 INR in 7 days
4.9
4.9

Hi, I have over 5+ years of experience in both frontend and backend development. I will do the specified tasks. Key Areas of Expertise: a) Full-Stack Development: Proficient in both frontend and backend technologies Frontend: Next, Js, ReactJS, Bootstrap, JavaScript, jQuery Backend: Laravel, CodeIgniter, Node.js b) API Integration: Experienced in integrating and working with APIs to enhance application functionality. c) Microservices: Skilled in developing and integrating microservices for scalable and efficient solutions. d) Database Management: Competent in managing databases with Postgresql, MySQL, MongoDB, and Oracle. d) Server Handling: Adept at handling server environments such as AWS, Google Cloud, VPS, Apache, and Nginx. Lets connect in chat so that We discuss further. With Regards, Sai
₹4,300 INR in 3 days
4.6
4.6

Hi, I'm interested in supporting your Delta PLC production-counting project, particularly the Python Modbus integration, communication testing, and data validation. My background includes Python, C#, .NET, electronics, embedded systems, and automation. I can contribute to: - Python PyModbus 3.15 integration with the Dell Linux server - Modbus RTU communication testing at 9600 baud, 8N1 - Register mapping and data validation - Reading and independently resetting 32-bit production counters - Work Order ID, target quantity, and status synchronization - Communication recovery and error handling - Automated testing and logging - Power-failure recovery test procedures - Technical documentation I would recommend working alongside an experienced Delta DVP/SS2 PLC programmer for the ISPSoft/WPLSoft ladder logic, hardware-specific high-speed counting, and retentive memory configuration. My proposed budget for the Python integration and testing component is ₹8,000 INR, subject to the agreed scope. Could you confirm whether you already have the PLC ladder program or need the complete PLC logic developed from scratch? Best regards, Ankit
₹8,000 INR in 2 days
4.6
4.6

I can develop the Delta DVP14SS211R PLC program with reliable 32-bit production counters for all 8 inputs, configurable debounce and pulse lockout, and non-volatile storage for counter values and work-order data. I’ll configure the Modbus RTU RS485 slave for 9600 baud, 8N1, slave ID 10, with a clear register map for your Python PyModbus server to read, reset counters independently, manage work orders, and control relay outputs with appropriate interlocks. I’ll also focus on reliable 24/7 operation, power-failure recovery, communication error handling, and testing to ensure the counting system performs consistently at your expected production rates. The deliverables will include the editable PLC project, Modbus register documentation, and remote installation and commissioning support. I work with industrial automation, PLC/HMI programming, and Modbus-based machine control, and I can help implement this as a clean, maintainable system with all production and work-order business logic remaining on your Dell server.
₹7,000 INR in 7 days
4.2
4.2

I specialize in embedded firmware and industrial communication protocols, with hands-on experience implementing Modbus RTU slave stacks on resource-constrained controllers — directly applicable to the DVP14SS211R. For this project I will: Configure Modbus RTU slave at 9600 baud, 8N1, ID 10, fully compatible with PyModbus 3.15 on your Dell Linux server. Implement 8 independent 32-bit counters (using paired D registers with retentive memory) mapped to X0–X7, overflow-safe well beyond 15,000 pulses/day. Add per-channel debounce and pulse-lockout timers (100–2000 ms), each individually writable via Modbus holding registers so your server controls filtering without reflashing. Store all counter values and work-order data (ID, target quantity, status) in retentive data registers to survive power cycles. Expose clean read/reset commands and relay output control registers, with hardware safety interlock logic kept inside the PLC — no business logic on the PLC side. Deliver full Modbus register map documentation and remote installation support. I have worked on 24/7 industrial systems and understand the reliability requirements for continuous production environments. I will provide the complete editable DVP-SS2 program along with power-failure and communication-recovery test results before handover. Ready to start immediately. Let’s connect to discuss timeline.
₹7,000 INR in 7 days
3.4
3.4

Hi, a counting program for your DVP14SS211R that Dell polls over RS485 as slave 10. The fiddly part is debounce plus lockout per input, set live from registers. How we would build it: COM2 at 9600 8N1, edge detection on X0 to X7 into 32 bit counters in latched D registers, then a holding register block per machine for count, reset, debounce, lockout, work order, target and status. Relay writes go through an interlock rung. Then we test power cuts and cable pulls against PyModbus. Are the sensors NPN or dry contacts? Happy to start with the register map and X0 counting as milestone one. Regards, Digitalizers
₹5,250 INR in 7 days
3.1
3.1

Hi, I see the Delta DVP14SS211R PLC needs to handle 15,000 pulses per day from each machine, which requires careful configuration of the Modbus RTU slave communication. I'd approach this by setting up independent 32-bit counters for each digital input, ensuring they can handle millions of counts without overflow. This will involve configuring the PLC program to preserve counter values during power failures. I've found that a common mistake in PLC programming is not properly handling debounce and pulse lockout, which can lead to inaccurate counts. To fix this, I'll configure each input to support individually adjustable debounce and pulse lockout from 100-2000 milliseconds, controlled through Modbus registers. The client can expect reliable operation during continuous 24x7 factory use, with the ability to read and reset each counter independently through Modbus.
₹5,000 INR in 5 days
2.5
2.5

My 10+ years of professional experience and 300+ completed projects in automation and software development make me well suited to connect your Delta PLC production-counting system with the Dell Linux server. I specialise in Python automation and API/integration work, which aligns directly with your PyModbus-based Modbus RTU architecture. I can develop the server-side communication and supporting logic required for reading, resetting, and managing the eight machine counters, work-order data, configurable timing values, and relay commands while keeping business logic on the Dell server as specified. I focus on dependable, maintainable systems designed for real operational use, with clear communication and practical technical guidance throughout the project. I would be glad to contribute my automation and Python experience to deliver a reliable factory-counting integration.
₹2,500 INR in 2 days
2.3
2.3

Experienced with Delta PLCs and Modbus communication, I’ll configure your DVP14SS211R for efficient pulse counting and Modbus RS485 control, ensuring robust 24×7 operation. Let’s discuss specifics on integrating 32-bit counters and debounce settings to optimize your production system. Have any unique challenges faced?
₹7,000 INR in 7 days
0.0
0.0

I can deliver 'Delta DVP14SS211R PLC Programming' end to end — clean architecture, tests, and deployment. I'll start with a short plan, share progress daily, and hand over production-ready code. Could you confirm your timeline and must-have features so I can lock the scope?
₹5,854.38 INR in 7 days
0.0
0.0

I can program the Delta DVP14SS211R PLC to implement the required Modbus RTU RS485 counters, debounce settings, data retention and relay control for your 24×7 production line. I can send a free sample of 10 rows of the Modbus register mapping, built from public data only. Introductory fixed price: INR 3000; timeline: 20 day(s) after scope agreement. Fixed scope: the three steps below, confirmed before starting. Pay on approval of that agreed scope through Freelancer. 1. Configure the PLC as a Modbus RTU slave (9600‑baud, 8N1, ID 10) and define registers for each of the eight counters, debounce settings, work‑order data and relay outputs. 2. Implement 32‑bit independent counters with configurable debounce and pulse‑lockout timers (100‑2000 ms) and test overflow handling up to millions of pulses. 3. Add non‑volatile storage routines to retain counter values and work‑order information across power loss, and verify communication recovery with the Dell server. Could you confirm whether the PLC’s existing I/O modules support the required 24 V safety interlocks for the relay outputs? Joseph C
₹3,000 INR in 20 days
0.0
0.0

Hi, I am excited to apply for the Delta PLC programming project focused on Modbus RTU RS485 machine counter integration. With over 3 years of hands-on experience in programming and automation, I have developed a strong proficiency in working with various PLC systems, including Delta PLCs. I understand the importance of precise and efficient programming for your machine counter. My approach will ensure seamless communication between the PLC and the Modbus RTU protocol, enabling accurate data collection and control. Here’s how I plan to deliver on your requirements: - Analyze your existing setup and requirements for the machine counter. - Develop and implement Delta PLC programs tailored to your specifications. - Ensure robust Modbus RTU communication for reliable data transfer. - Conduct thorough testing to validate functionality and performance. - Provide documentation for future reference and maintenance. I am committed to delivering high-quality results that meet your operational needs while ensuring minimal downtime. I look forward to the opportunity to contribute to your project. Best regards, Shyam Prajapati
₹10,005 INR in 10 days
0.0
0.0

Hi, I read your project "Delta DVP14SS211R PLC Programming". I'm a senior engineer (11+ yrs) specialized in full-stack development (front-end + back-end, databases, cloud deployment), which is exactly what this needs. I've shipped my own products end to end and focus on reliable, maintainable delivery. How I'd approach it: 1) Confirm the exact scope and edge cases with you 2) Build in small, testable steps so you see progress early 3) Clean handover with docs Ready to begin immediately. Ask me anything. Best, Chris
₹5,400 INR in 1 day
2.4
2.4

Hi there, I read your project "Delta DVP14SS211R PLC Programming" and it lines up well with my experience in Python. I've been doing this kind of work for 9 years and focus on clean, well-tested code and clear communication. Before starting I'd like to confirm a couple of details about the scope so the result matches exactly what you need. Happy to jump on a quick chat. I can deliver in 1 days for ₹7136 INR. Best regards, Siddharth Kasherwal
₹7,136 INR in 1 day
0.0
0.0

Python expertise makes me well suited to the Dell Linux integration side of your Delta PLC production-counting system, particularly the PyModbus-based communication and reliable exchange of counter and work-order data. I build automation solutions using Python, APIs, databases, and practical workflow integrations. This aligns with your requirement for dependable Modbus communication between the server and PLC, independent counter access, reset handling, work-order data exchange, and recovery after communication interruptions. My programming background also supports creating clear, editable integration code and register handling for continuous factory operation. I would be glad to contribute to this industrial counting solution and support the Modbus/Python implementation, testing, and remote installation requirements. Choose me to help connect your Dell server reliably with the Delta PLC.
₹7,000 INR in 2 days
0.0
0.0

Ludhiana, India
Payment method verified
Member since Jan 12, 2025
₹600-1500 INR
₹600-1500 INR
₹1500-12500 INR
₹1500-12500 INR
₹1500-12500 INR
₹1500-12500 INR
₹1500-12500 INR
$250-750 USD
₹600-1500 INR
$30-250 USD
$25-50 CAD / hour
$250-750 USD
$25-50 USD / hour
$250-750 USD
₹750-1250 INR / hour
$250-750 USD
₹1500-12500 INR
$30-250 USD
£1500-3000 GBP
$15-25 USD / hour
₹400-750 INR / hour
$150-200 USD
$250-750 USD
$30-250 USD
₹37500-75000 INR