I'm seeking a skilled professional to troubleshoot communication problems on my M-bus network. I have been able to log in to datalogger but all meters are coming back as not reading for provide a reading of 0 kWh. Ideal skills and experience: - Expertise in M-bus systems - Strong problem-solving abilities - Experience with communication protocols and network diagnostics Please provide a detailed approach to resolve the issues.
Project ID: 40655368
21 proposals
Remote project
Active 1 day ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
21 freelancers are bidding on average £435 GBP for this job

As a seasoned network professional with extensive experience in Cisco, Computer Security, Network Administration, and many more fields you mentioned looking for help with, I genuinely believe I could be your ideal choice for this task. With over 10 years of hands-on expertise, I am well-versed in all aspects of M-bus systems and the complexities that arise out of them. My approach towards MEP projects is based fundamentally on resolving issues innovatively while employing best practices. You mentioned having trouble with the datalogger and meters showing zero readings; I will employ my problem-solving skills to troubleshoot extensively, paying close attention to your entire M-bus network. With Cisco ASA, Fortinet, Palo Alto, SonicWall and other network security vendors under my belt, I have finely-honed abilities to diagnose communication problems and resolve them promptly and efficiently. My commitment to project delivery stands firm and I guarantee nothing short of detailed and comprehensive solutions within the agreed-upon timeline. Beyond technical know-how, I offer timely communication- never leaving you clueless about progress or solutions. So, give me the chance to align your M-bus network with its true potential again. Let's revamp things together!
£400 GBP in 4 days
7.3
7.3

With an extensive background in computer security and troubleshooting, I believe I'm the perfect fit for your M-Bus network troubleshooting project. My breadth of skills and experience extends not only to M-Bus systems but also to various server operating systems, web servers, and more mentioned in your project description. This should give you the assurance that I have a deep understanding of network protocols, communication systems, and network diagnostics - exactly what you need to resolve your issues. ing complex puzzles by troubleshootingg to your project and together we can rectify this issue.
£500 GBP in 1 day
6.7
6.7

As a seasoned IT infrastructure and network engineer with 14+ years of hands-on experience specifically in troubleshooting, I can provide you a comprehensive solution to the M-Bus network issues you're experiencing. Over the years, I've honed my skill set and acquired expertise in dealing with a wide range of complicated system malfunctions, making me adaptable and highly efficient when facing unique problems such as yours. In addition to my marked proficiency in networking, including extensive work with Cisco networking solutions, I have an intimate familiarity with communication protocols and network diagnostics. This knowledge allows me to quickly locate faults in your M-bus network while also enabling me to work backward from the problem's source to its root cause. This investigative approach has proved incredibly valuable in preventing recurring problems. Pairing this with my robust experience in setting up secure, reliable networks makes me confident that I am your best-suited professional for this project. Let's troubleshoot this network together and get your meters back on track!
£280 GBP in 1 day
5.7
5.7

Hello, I can troubleshoot and resolve the communication failures on your M Bus network and datalogger. My plan is to start by auditing the datalogger serial communication settings to verify baud rate framing matching the standard 2400 baud 8E1 configuration. I can check the physical M Bus line voltage to ensure the master converter supplies proper space state voltage around 30 to 36 volts DC and check for short circuits. I can run primary and secondary address scanning from the datalogger interface using meter serial numbers to resolve address collisions. I can also analyze raw M Bus frame logs like SND_NKE initialization and REQ_UD2 data requests to confirm meter response telegrams and fix payload parsing errors in your datalogger. 1) What is the exact brand and model of your M Bus datalogger or master converter? 2) Are the energy meters configured using primary addresses or secondary addresses like 8 digit serial numbers? 3) Can we access the datalogger diagnostic logs or terminal interface during a remote session? Thanks, Bharat
£550 GBP in 7 days
5.2
5.2

HI, KINDLY READ THROUGH MY PROPOSAL I will diagnose and resolve the communication issues on your M-Bus network so that all meters report correct readings instead of 0 kWh. MY APPROACH ✅ Check physical layer (wiring, polarity, bus voltage, termination and cable length) ✅ Verify primary/secondary addressing, baud rate and master configuration in the datalogger ✅ Test individual meters and isolate faults (short circuits, missing power, incorrect addresses or failed devices) DELIVERABLES - Root-cause diagnosis - Corrected configuration and working meter readings - Short report of the changes made QUESTIONS 1. How many meters are on the bus and what is the approximate cable length? 2. Can you share the datalogger model and any error messages or screenshots? Ready to start immediately.
£250 GBP in 3 days
3.9
3.9

Hi there! It looks like the datalogger is accessible, but the M-Bus meters are not communicating correctly and are returning 0 kWh readings. I have experience with network troubleshooting, communication protocols, device connectivity, and diagnosing issues between field devices and data collection systems. I can investigate the M-Bus setup and identify whether the issue is with wiring, addressing, configuration, communication, or the meters themselves. My approach will start by checking the datalogger configuration and M-Bus communication status. I will verify meter addresses, baud rate and protocol settings, then review network wiring, termination, power levels, and communication logs. After identifying the root cause, I will apply the required configuration changes and verify that actual meter readings are being received correctly. check our work https://www.freelancer.com/u/ayesha86664 Can you share the datalogger model, M-Bus setup details, and any available communication logs? Let me know if you’re interested & we can discuss it. Best Regards Ayesha
£500 GBP in 3 days
2.4
2.4

I can help troubleshoot the M-Bus communication issue end to end. Since the datalogger is online but all meters report not reading / 0 kWh, I would approach this systematically: verify the physical bus layer, confirm M-Bus master polling settings, check primary/secondary addressing, validate baud rate and telegram format, then inspect meter response frames and error patterns. The key is to isolate whether the issue is wiring/power, address mapping, or a configuration mismatch between the datalogger and the meters. I will review the logger’s meter table, communication logs, and any read attempts to identify where the chain breaks. From there, I can recommend precise changes and confirm recovery with test reads and consistency checks across the network. I focus on practical diagnostics, fast root-cause identification, and a clear resolution path so the meters return valid readings reliably.
£650 GBP in 8 days
0.0
0.0

This project immediately caught my attention because it is exactly the type of work I do best. I understand you're facing communication problems on your M-bus network, with all meters returning a reading of 0 kWh. I have extensive expertise in M-bus systems and strong problem-solving abilities, specifically with communication protocols and network diagnostics. I can provide a clean, professional, and user-friendly approach to troubleshooting and resolving these issues. While I am new to freelancer, I have tons of experience and have done other projects off site. If this sounds like what you're looking for I'd love to hear more about your project. Regards, Warrick Van Eeden
£350 GBP in 7 days
0.0
0.0

Hello, I can help diagnose and resolve the communication issues on your M-Bus network. Since the datalogger is accessible but all meters are reporting 0 kWh or not reading, the problem is likely related to M-Bus communication, meter addressing, wiring integrity, bus voltage, configuration, or polling settings. My approach will include reviewing the network topology, verifying M-Bus communication parameters, checking meter addresses and scan results, analyzing datalogger logs, and identifying any communication faults between the master and connected meters. I will then perform targeted troubleshooting to restore reliable meter readings and validate data collection. I have experience with network diagnostics, communication protocols, and troubleshooting field devices, and I can assist remotely by reviewing configuration files, logs, and screenshots or guide on-site testing if required. I look forward to helping you get the system fully operational. Thank you.
£500 GBP in 7 days
0.0
0.0

Greetings! I can troubleshoot your M-bus network communication issues where meters are returning zero readings. I have experience with M-bus systems and network diagnostics. I will check wiring, termination, polarity, and device addressing, and verify the datalogger configuration. I can provide a step-by-step approach to resolve the issue. Let me know your system details and I will begin. Thanks, Revival
£250 GBP in 7 days
4.1
4.1

As an experienced network engineer with a proven track record in troubleshooting complex systems, I have the skills and expertise you need to solve the communication problems on your M-bus network. I have extensive experience in working with M-bus systems, familiar with various communication protocols, and a knack for identifying and resolving issues efficiently. My troubleshooting abilities combined with deep knowledge of computer security will ensure that not just the problem gets fixed but also that we safeguard your system from any threats or vulnerabilities. My proficiency in network diagnostics gives me an edge when it comes to swiftly identifying root causes and implementing effective solutions. Moreover, my commitment to providing top-grade services at affordable rates aligns perfectly with your project requirements. With me, you can expect timely delivery and relentless effort to ensure 100% satisfaction. I'm confident that collaborating with me will result in a more robust M-bus network for your organization. Let's get started on finding the cause of those 0 kWh readings and restoring normal operations.
£750 GBP in 1 day
0.0
0.0

Hi there! Quick question - have you checked whether your M-bus repeaters or power supplies are functioning properly, or is this purely a communication/configuration issue on the datalogger side? Regardless, this is definitely something that I feel confident delivering on, given my past experience. I would love to discuss your project further! Looking forward hearing from you. kind regards, Corné
£450 GBP in 7 days
0.0
0.0

I understand you're facing communication challenges within your M-bus network, specifically with your datalogger displaying all meters as returning 0 kWh readings. This can be frustrating, especially when accurate data is critical for your operations. My approach begins with a thorough assessment of your M-bus system, focusing on the communication pathways between the datalogger and each meter. I'll perform diagnostics to identify potential issues, such as faulty wiring, configuration errors, or protocol mismatches. By systematically isolating each component, I can pinpoint the root cause of the problem. Once the issue is identified, I'll implement targeted solutions, which may include recalibrating devices, updating firmware, or adjusting network settings to ensure seamless communication. My goal is to not only restore functionality but also enhance the reliability of your entire system. By addressing these issues with precision, you'll gain accurate readings and improved operational efficiency, allowing you to make informed decisions based on reliable data. Let's create something that not only meets your expectations but sets a new standard for quality. Regards Junaid
£300 GBP in 7 days
0.0
0.0

Hi, I can help troubleshoot this M-Bus issue. Could you please provide: * Meter, M-Bus gateway/master, and datalogger make/models * Number of connected meters * Whether the datalogger detects the meters or shows them as offline * Any error messages/logs or screenshots * When the issue started and whether anything changed * Whether remote access to the datalogger/gateway is available This will help me determine whether the issue is communication, configuration, or meter data mapping. Best regards, Francesca
£500 GBP in 2 days
0.0
0.0

Dublin, United Kingdom
Member since Aug 18, 2026
$10-30 USD
£250-750 GBP
₹600-1500 INR
$25-50 USD / hour
$25-50 USD / hour
min $50 USD / hour
₹1500-12500 INR
$30-250 USD
₹1500-12500 INR
$30-250 USD
₹600-1500 INR
$250-750 USD
$30-250 USD
$50-60 AUD / hour
$30-250 NZD
$25-50 USD / hour
₹750-1250 INR / hour
₹750-1250 INR / hour
$30-250 USD
$10000-20000 CAD