
Closed
Posted
Paid on delivery
I am looking for a qualified HVAC engineer to verify whether the existing ventilation in our industrial manufacturing area still meets current standards and our production needs. I will supply you with detailed field data: measured airflow rates at each supply and exhaust point, full room dimensions and volume, exhaust-fan performance curves, occupancy numbers per shift, and other relevant observations taken on site. With this information I need you to: • perform fresh-air and extraction calculations in line with recognised codes such as ASHRAE or local equivalents, • highlight any shortfalls or over-capacity you find, • provide clear recommendations—either confirmation that the system is adequate or specific upgrades (for example fan sizing, additional air changes, or filtration improvements) if it is not. Please return a concise engineering report that shows your calculations, assumptions, and conclusions so we can decide on next steps with confidence.
Project ID: 40719245
15 proposals
Remote project
Active 2 hours ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
15 freelancers are bidding on average $179 USD for this job

Dear Sir, Please contact me to get started. Thanks. I am a Professional Mechanical Design Engineer with 17+ years of experience in HVAC system design. I successfully completed the design, drafting and installation of complete HVAC System for various Residential and Commercial Projects as per standards and specifications. I have all the technical skills, experience, and practical project management skills to complete your task professionally and quickly. I will provide all the services as per your requirement. Proficient in AutoCAD, Revit MEP and more. Well-versed in, HVAC Detail Design Layout Complete Equipment Selection based on load and Schedule. Ductwork and Air Distribution Systems Air Filtration and Purification Systems Detailed Equipment Installation Details Duct Sizing Calculation and Routing Cooling and Heat Load Report Ventilation Calculation Report Split Units Manual J, D and S VRF system Design Chillers Air Conditioners Cooling Towers Kitchen Hood Ventilation Heat exchangers Takeoff Sheets Bills of Quantity Technical Specification and more
$220 USD in 5 days
3.7
3.7

Hello, I can assess the existing industrial ventilation system using your measured field data and determine whether the current fresh-air and extraction rates are adequate for both applicable standards and your production requirements. I can perform the required ventilation calculations based on the supplied room dimensions, measured supply/exhaust airflow, occupancy, exhaust-fan performance curves, and site observations. The assessment can include required fresh air, extraction rates, ACH, and comparison of actual versus calculated requirements. I will clearly identify: * Ventilation shortfalls or excess capacity * Areas requiring additional airflow or extraction * Fan capacity/performance issues * Potential filtration improvements * Other relevant HVAC deficiencies Where upgrades are required, I will provide practical recommendations such as revised fan capacity, additional extraction/fresh-air requirements, increased ACH, or filtration modifications. If the existing system is adequate, the report will document the basis for that conclusion. The final deliverable will be a concise engineering report containing the design criteria, input data, assumptions, calculations, comparison tables, findings, recommendations, and conclusion. I can work with ASHRAE criteria and the applicable local requirements once the project location and governing standard are confirmed. I’m ready to review your field data and begin the assessment. Best regards,
$100 USD in 7 days
1.4
1.4

The risk is verifying existing ventilation against current standards and production needs using your field data. I will perform fresh-air and extraction calculations using ASHRAE standards. I’ll use your measured airflow, room dimensions, fan curves, and occupancy data in these calculations to highlight any shortfalls or over-capacity, then provide clear recommendations on system adequacy or specific upgrades like fan sizing or increased air changes. What is the specific local code equivalent you'd like me to prioritize alongside ASHRAE? I need your field data to begin. My 5.0 rating across 10 reviews here also confirms I deliver.
$140 USD in 21 days
0.0
0.0

Hello, I reviewed the requirements, and the core challenge is determining whether the measured supply and exhaust performance actually satisfies the required fresh air, extraction, occupancy, and production conditions rather than simply checking airflow figures in isolation. I would analyse the field measurements, room volumes, fan curves, occupancy, and applicable ASHRAE or local requirements, then document any shortfalls, excess capacity, assumptions, and practical upgrade options in a clear engineering report. I have worked on similar HVAC ventilation calculations, system assessments, and engineering documentation projects and can share relevant examples once we connect in chat. Also a quick question, which country and specific industrial process or contaminants should the ventilation assessment be based on? Best Regards, Muskan
$30 USD in 1 day
0.0
0.0

Hi, Does the existing ventilation system still provide sufficient fresh air and extraction for your industrial manufacturing area under current production and occupancy conditions? We can review your measured airflow data, room dimensions, fan performance curves, occupancy, and site observations to perform accurate ventilation calculations against applicable ASHRAE or local requirements. With more than eleven years of experience in CAD modeling, engineering design, and technical documentation, we bring a detail-focused approach to evaluating technical systems and presenting clear engineering information. We will identify airflow shortfalls or excess capacity, assess air changes and extraction requirements, and recommend practical improvements such as fan adjustments, additional ventilation, or filtration upgrades where required. The final concise report will clearly document calculations, assumptions, findings, and recommendations for confident decision-making. Best Wishes
$250 USD in 5 days
4.0
4.0

Hi there, You need an HVAC engineer to verify whether your existing industrial ventilation meets current standards and production needs. You have already collected the field data—now you need a clear, calculation-based engineering report with actionable recommendations. This is exactly what I do. Why I am a strong fit: HVAC & Ventilation Expertise: 8+ years in HVAC design, ventilation analysis, and ASHRAE-compliant calculations for industrial and commercial projects. Report Writing: I prepare concise engineering assessments that show calculations, assumptions, and conclusions—translating complex data into decision-ready recommendations. Practical Recommendations: If shortfalls are found, I provide specific upgrades (fan sizing, air changes, filtration improvements) with clear justification. My Approach: Review your field data (airflow rates, room dimensions, fan curves, occupancy). Perform fresh-air and extraction calculations per ASHRAE or local equivalents. Compare required vs. actual performance to identify shortfalls or over-capacity. Deliver a concise report with calculations, assumptions, conclusions, and specific recommendations. Could you please share: A brief description of the industrial process and contaminants (if any). The total number of supply and exhaust points. Your preferred deadline. I am available to start immediately. Best regards,
$150 USD in 10 days
0.0
0.0

Hi, Checking an existing ventilation system against the codes using measured data is straightforward work for us, and the field data you listed covers what is needed. What we would do: - work out the fresh air required under ASHRAE 62.1 (or your local code) from the floor area and people per shift, plus the extract your process needs - compare that with your measured supply and exhaust at each point, and check where each fan is operating on its curve - calculate the actual air changes per hour and flag any area that is short or oversized - if something falls short, size the fix (fan upgrade, more air changes, better filtration) with the numbers behind it You would get a short report with the calculations in tables, the assumptions stated clearly, and a plain answer on whether the system is adequate. What does the area produce? Fumes, dust or heat from the process can drive the extract rate much more than the number of people does. Thanks, CORE team
$180 USD in 3 days
0.0
0.0

Tbilisi, Georgia
Member since Jan 12, 2024
$10-5000 USD
$250-500 USD
$250-750 USD
$250-750 USD
$15-25 USD / hour
₹12500-37500 INR
€250-750 EUR
$30-250 USD
₹12500-37500 INR
$250-750 USD
$10-30 USD
$250-750 USD
£1500-3000 GBP
$30-250 AUD
£1500-3000 GBP
$30-250 USD
$250-750 USD
$15-25 USD / hour
$250-750 USD
$30-250 USD
$10000-20000 CAD