Open
Posted
•
Ends in 2 days
I need a detailed fire safety code compliance analysis for an existing residential building in Wyoming. The project involves converting the structure from R1 short-term residential to R2 long-term residential. The State Fire Marshal requires stamped as-built drawings and a comprehensive code analysis of the existing structure to determine necessary fire safety updates. Must be a licensed engineer in Wyoming, USA. Ideal skills and experience: - Expertise in fire safety regulations, particularly for R2 classification - Familiarity with residential building codes in Wyoming - Experience in conducting code compliance assessments - Ability to provide stamped as-built drawings and detailed reports with recommendations Please include examples of past work in your application.
Project ID: 40630918
4 proposals
Open for bidding
Remote project
Active 4 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
4 freelancers are bidding on average $55 USD/hour for this job

The R1 to R2 conversion is where the fire safety code compliance is most tested, especially with the State Fire Marshal’s stamp requirement for as-built drawings. I will produce the stamped as-built drawings using AutoCAD, basing them on the existing structure and overlaying code requirements, so the analysis is visual. The comprehensive code analysis will focus on Wyoming residential building codes and specifically R2 classification requirements, identifying all necessary fire safety updates. I will provide a detailed report with those recommendations. I will not be using generic code templates for the analysis. The specific nature of an R1 to R2 conversion demands a detailed look at the existing structure, not a general application of rules. What is the current occupancy classification and duration for the R1 designation? I need the current building plans or a site visit for accurate as-built drawing creation. Once I have that, I will send the detailed approach and preliminary timeline. Preferred Freelancer here, and I have not missed a deadline or gone over an agreed price yet.
$50 USD in 7 days
3.1
3.1

Dear Sir, I am a Professional Mechanical Design Engineer with 18+ years of experience in all aspects of Fire Protection and detection System. I completed the design, drafting and installation of Automatic Fire Sprinklers, fire suppression, Fire alarms, firefighting, Plumbing and Electrical systems for various Residential and Commercial Projects as per standards and specifications. I have all the technical skills, experience, and practical project management skills to complete your task professionally and quickly. I will provide all the aspects of Fire Protection and Detection System in Revit as well as AutoCAD. 1. Fire Sprinkler Design Layout as per NFPA 2. Plumbing and Piping Expertise 3. Collaboration and Communication 4. Fire Hose Reel System 5. Fire Hydrant System 6. Fire Hydraulic Calculations Report 7. Pump Room Sizing and Fire pump room selection and detail 8. Fire Alarm system 9. Extensive knowledge of fire suppression systems 10. Technical Writing 11. Report Writing 12. Equipment Schedule 13. Bills of quantity 14. Technical Specifications and more
$50 USD in 40 days
0.0
0.0

Denver, United States
Member since Aug 6, 2026
$750-1500 USD
min $50 USD / hour
$250-750 USD
min $50 USD / hour
$30-250 USD
$10-30 USD
₹12500-37500 INR
$250-750 USD
$1500-3000 USD
$750-1500 USD
₹12500-37500 INR
$250-750 USD
$3000-5000 USD
₹750-1250 INR / hour
$10-30 USD
$25-50 AUD / hour
$750-1500 AUD
₹12500-37500 INR
$250-750 USD
$30-250 USD