Closed
Posted
Paid on delivery
Hi, I'm looking for a structural engineer to carry out a wind load assessment and foundation/anchor design calculation for a stacked shipping container structure, with a stamped calculation pack suitable as formal sign-off. The structure: • Three 40ft high-cube shipping containers, stacked 3 high (9'6" / 2.9m height each, so approx. 8.7m total stack height) • Standard ISO steel construction, corner-casting to corner-casting stacking • Site located in Solihull, West Midlands • Open yard setting — no significant surrounding shelter from adjacent structures What I need: 1. Wind load assessment to BS EN 1991-1-4, appropriate to the site location and exposure category 2. Overturning moment and corner reaction calculation (uplift and shear) at ground level, and at each inter-container connection level 3. Foundation and ground anchor design — footing sizing and anchor bolt specification suitable for the calculated loads 4. A stamped/signed calculation pack I can retain as documentation I'm not converting these into habitable/occupied space but they’ll be used to house activated carbon and have an access gentry to change out dust filters, I want the installation properly engineered and documented given the height and wind exposure. Could you let me know: • Whether this is something you're able to take on • What information you'd need from me to scope and quote (site plan, container spec sheets, any ground condition info) • Indicative cost and turnaround time • Happy to provide photos of the site and any further detail needed.
Project ID: 40727309
27 proposals
Active 6 days ago
Location: United Kingdom
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
27 freelancers are bidding on average £1,040 GBP for this job

Drawing on my extensive experience in civil and structural engineering, I am more than capable of taking on your shipping container project. I have a keen understanding of the various forces that impact structures and am well-versed in codes such as BS EN 1991-1-4. Leveraging this knowledge, I can conduct a thorough wind load assessment and design appropriate foundations and anchors to ensure the safety and stability of your stacked containers. Being an architectural engineer, I bring a unique perspective to your project - one that balances aesthetics with functionality and sustainability. Although the containers won't be used for habitation, their height and exposed nature make it crucial to integrate proper engineering techniques, ensuring they can withstand their intended purpose, extreme weather conditions included.
£750 GBP in 1 day
8.5
8.5

Greetings I am a structural engineer in Mexico I can do but i cannot stamp it for you But i kniw all British standard
£1,500 GBP in 7 days
8.1
8.1

Being a multi-skilled engineer, CAD designer and draftsman means I'm equipped to handle your structural challenge with precision and creative problem-solving. I possess solid expertise in AutoCAD which would be crucial in generating the detailed engineering drawings that will be required for the wind load assessment, overturning moment calculation, foundation, and anchor design. My experience extends to using BS EN norms and standards, making me well-versed in ensuring code compliance where safety is concerned. My previous work incorporates designing complex structures to withstand terrains and exposures similar to yours. Even though these containers won't be used as habitable spaces, I completely understand how crucial it is for each aspect of the structure to be engineered to withstand possible threat factors given their importance inhouse activated carbon. Safety, precision, and documentation are my top priorities throughout the project; a custom stamp calculation pack is guaranteed.
£766 GBP in 1 day
6.8
6.8

As an experienced structural engineer, I have worked on a variety of projects involving wind load assessment, foundation and anchor design calculations, which makes me well-suited to take on your shipping container stack project. My knowledge in AutoCAD grants me the ability to ensure precise and accurate calculations for the overturning moment, corner reactions and footing sizing critical to your project. To compliment my expertise in structural engineering, I am well-versed in CAD drafting and can provide detailed, stamped calculation packs that you seek for formal sign-off. My broad understanding extends beyond theoretical designs to practical solutions that meet strict industry standards. Furthermore, my geographical proximity to Solihull ensures easy and prompt access to the site. My tenacity combined with proficiency will ensure a thorough wind assessment unique for your location providing you with a effective solution at an affordable price within a reasonable turnaround time. Let me be the one who turns your vision into robust reality while accounting for the detail-oriented aspects specific to housing activated carbon.
£752 GBP in 1 day
6.0
6.0

I understand you require a stamped calculation pack for a three-high stacked shipping container structure, including wind load assessment and foundation/anchor design. My experience with similar projects involving modular structures and complex load calculations ensures I can deliver a robust and compliant design. My approach will involve applying BS EN 1991-1-4 for wind load calculations, considering the specific site exposure in Solihull and the geometry of the container stack. I will then utilize BS EN 1997-1 for the geotechnical and structural design of the foundation and anchor system, ensuring adequate resistance to overturning and sliding. The final output will be a comprehensive, stamped calculation pack suitable for formal sign-off, detailing all assumptions, calculations, and design outcomes. To ensure we're perfectly aligned, could you confirm the specific wind speed zone for Solihull that should be used for the design? Also, are there any specific foundation types you are considering or wishing to exclude? I'm available to discuss your project further at your convenience.
£1,308 GBP in 21 days
5.6
5.6

Hello, I fully understand your needs, as I have previously worked on a project similar to your specifications. I am an experienced architect specializing in 3D design and rendering. I have extensive experience using AutoCAD, SketchUp, and Revit 2027, and I can deliver the required design drawings on time. I would be delighted to work on your project. I have carefully reviewed your project details. If you choose me, your project will be completed quickly and to a high standard. Thank you for your interest.
£1,125 GBP in 7 days
6.0
6.0

Hello, I have experience with wind-load, overturning, anchorage, and foundation design for steel and container-based structures, including stacked configurations exposed to open-site wind. I am a good fit because I can calculate actions to BS EN 1991-1-4, determine uplift/shear reactions at each container interface, and develop a practical foundation and anchor solution. I will assess site wind exposure, container geometry, connection forces, overturning stability, footing sizes, anchor bolts, and ground reactions, then compile the results into a clear calculation pack. I do not personally hold UK chartered engineering registration, but I work with appropriately qualified UK structural engineers who can review and sign the final calculations where formal sign-off is required. Final delivery will include the signed calculation report, foundation/anchor details, assumptions, and design reactions for the three-storey stack. Thanks for reading my proposal. Edwin
£1,000 GBP in 6 days
5.4
5.4

Hi there, With over 56 projects completed, maintaining a stellar 4.9-star rating and a 96% on-time delivery rate, I am confident in my ability to undertake your structural engineering needs for the shipping container stack project. My broad-range of skills includes precise use of software such as AutoCAD and robust structural engineering methodologies that are crucial for this venture. Especially well-versed in steel construction, I am accustomed to handling ISO containers like the ones you'll be utilizing for activated carbon housing. Additionally, my experience designing grounding and foundations specifically tailored to withstand wind loads will ensure your installation is engineered and documented exactly as you need it. Best regards, Mobasher Reza
£1,125 GBP in 3 days
4.7
4.7

The risk is accurately calculating the wind load on the stacked containers, a critical factor for overturning moment and corner reaction calculations. I handle this by applying BS EN 1991-1-4 directly to the geometry of the three stacked 40ft high-cube containers, considering the open yard setting in Solihull, West Midlands to determine the appropriate exposure category and wind pressures. I will build the calculation pack using AutoCAD for any necessary drawings and Excel for the structural calculations. The overturning moment and corner reactions at ground level, and at each inter-container connection point, will be clearly detailed. I will use standard structural engineering principles for steel connections and foundation design, assuming a typical concrete slab foundation unless you specify otherwise. I will assume standard ISO shipping container dimensions and steel properties as per industry norms. What is the intended use of this stacked container structure, and are there any internal fit-outs planned that might affect the overall weight or wind profile? 10 reviews on Freelancer at 5.0, everything delivered on time and on the agreed price so far. I need your confirmation on the foundation type you envision before starting the calculations.
£1,244 GBP in 21 days
4.2
4.2

I am interested in working on your Structural Engineering for Shipping Container Stack project and can develop a practical structural assessment and design based on your container configuration, site conditions, loading requirements, and applicable design standards. I understand that stacked containers require careful consideration of vertical loads, lateral stability, connection details, bearing conditions, wind effects, and the structural capacity of the container corner posts and supporting elements. I can handle the calculation package. Please send the site info, container specs/weights, connection details, gantry loads, equipment loads, soil info and site photos. Then I can confirm price and turnaround. I will provide a well-organized structural design package containing calculations, engineering details, and drawings in the required format. The final deliverables will be prepared with accuracy, clarity, and constructability in mind, and I can incorporate revisions based on project requirements. Where professional engineering approval or stamping is required, the final documents can be reviewed and certified by an appropriately licensed engineer in the relevant jurisdiction.
£750 GBP in 7 days
5.2
5.2

I have completed similar structural engineering and load-calculation projects, including wind-load assessments, steel structures, foundation design, anchor calculations, and engineering documentation for fabrication and installation. I can develop the engineering calculation package for your three-high stacked 40ft high-cube container structure in Solihull, with particular attention to the exposed open-yard conditions and the stability of the full stack. Scope of Work Wind load assessment in accordance with BS EN 1991-1-4 Establish site wind parameters, exposure, pressure coefficients, and applicable factors Calculate wind actions on the stacked container arrangement Determine overturning moment and base reactions Calculate uplift and horizontal shear reactions at ground level Assess forces at each inter-container corner connection level Foundation sizing based on calculated reactions and assumed/provided ground conditions Ground anchor/bolt design, including required capacity and specification Check overall stability against sliding, overturning, and uplift Provide clear calculation sheets, assumptions, design criteria, and engineering conclusions Prepare a professional calculation pack suitable for review and project documentation what i will dwliver Detailed structural calculation pack Wind-load calculations Overturning and stability calculations Corner reaction schedules Foundation/footing design calculations Anchor bolt/ground-fixing design
£750 GBP in 5 days
0.8
0.8

Hi there, The three-high container stack requires verified wind actions, inter-container connection forces, overturning reactions, and a properly documented foundation and anchorage solution for the exposed Solihull site. I have strong expertise in solving exactly this type of structural engineering problem and will develop the assessment to BS EN 1991-1-4, establish wind pressures and load combinations, calculate connection-level and ground-level uplift/shear reactions, then design suitable footings and anchor bolts using the available container, site, and ground information. I will compile the assumptions, calculations, drawings or details required, and a clear signed calculation pack for formal review. My Engineering Drawing capability will support precise presentation of the structural details. Best regards, Marko
£1,250 GBP in 2 days
0.0
0.0

Hello! I can assist with the structural assessment of your stacked container system, including BS EN 1991-1-4 wind loading, overturning/uplift reactions, inter-container connection forces, and foundation/anchor design. I’ll produce a clear, professionally structured calculation package based on the site and container data, with the required review/sign-off arranged by an appropriately qualified UK engineer where applicable. With 6+ years of professional experience in 3D architectural visualization, I specialize in creating highly detailed 3D models, photorealistic renders, and compelling visual presentations using 3ds Max, SketchUp. Whether you need architectural visualization, product modeling, interior/exterior renders, or marketing visuals, I focus on accuracy, realistic materials, lighting, and refined details to ensure the final result effectively communicates your design. You can view my portfolio and previous work here: https://www.freelancer.com/u/muhammadj121 I’d be happy to discuss your requirements and bring your project to life. Best regards, Junaid
£750 GBP in 5 days
0.0
0.0

Greetings! I can carry out your wind load assessment and foundation and anchor design for the stacked shipping container structure in Solihull, and provide a stamped calculation pack suitable as formal sign-off. I will assess wind loading to BS EN 1991-1-4 for the open yard exposure, calculate overturning moments and corner reactions for uplift and shear at ground level and each inter-container connection, and design the foundation and ground anchors including footing sizing and anchor bolt specification for the calculated loads. To scope and quote, I will need the site plan, container spec sheets, any ground condition information, and photos of the site, and I will confirm indicative cost and turnaround once I review them. Thanks, Revival
£750 GBP in 14 days
0.0
0.0

Letchworth Garden City, United Kingdom
Member since Sep 22, 2026
$10-30 CAD
min $50 CAD / hour
₹500 INR
$10-1000 USD
₹12500-37500 INR
$50000-100000 USD
₹12500-37500 INR
$250-750 USD
₹1500-12500 INR
₹12500-37500 INR
₹1000-2500 INR
₹1500-12500 INR
$750-1500 USD
£20-250 GBP
€150 EUR
$250-750 USD
₹600-1500 INR
$250-750 USD
₹1500-12500 INR
₹600-1500 INR