Closed
Posted
Paid on delivery
I need a detailed CFD study that proves occupants can safely evacuate a 1600m2 car-park level during a single passenger-car fire. The focus is strictly on one parking level; ramps and additional floors are outside this scope. Your model should replicate the existing ventilation set-up (jet fans, extract system, inlets) and track smoke spread, layer height, temperature, visibility and tenability limits throughout the 10-minute design fire. I am interested in smoke clearance times, critical velocity, and whether visibility stays above life-safety criteria along the designated escape routes. I am comfortable with ANSYS Fluent, FDS or other recognised fire-engineered CFD tools, as long as the methodology is clearly documented and aligns with current fire-safety codes. Please run the mesh sensitivity check, explain boundary conditions, and provide screen-capture evidence that confirms convergence. Deliverables: • A concise report (PDF) summarising assumptions, model set-up, validation references and results • Plan and section snapshots showing smoke layer development and velocity vectors • Raw model files so I can peer-review or re-run if needed • A brief conclusions section stating whether the ventilation achieves smoke clearance for safe evacuation, plus any recommendations if it does not Let me know your preferred software, approximate turnaround, and the data you need from my side (drawings, fan curves, etc.) so we can get started right away.
Project ID: 40800106
38 proposals
Remote project
Active 20 hours ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
38 freelancers are bidding on average $458 USD for this job

Hi there, I can perform CFD-based smoke clearance evaluation using ANSYS Fluent to assess smoke movement, temperature distribution, airflow patterns, and clearance time under fire conditions. I have 7+ years of CAE experience with expertise in CFD, thermal-fluid simulations, and fire-related ventilation analysis. Deliverables: - 3D CFD model development and mesh independence study. - Fire and smoke propagation simulation. - Smoke concentration and temperature contours. - Air velocity and ventilation effectiveness analysis. - Smoke clearance time evaluation. - Assessment against applicable fire safety criteria. - Detailed technical report with recommendations. Do you have the building layout, ventilation system details, and design fire parameters available? Timeline and budget can be finalized after discussing the complete scope. Best regards, Arati M.
$500 USD in 7 days
6.8
6.8

Your car-park smoke-clearance evaluation requires an engineering-focused CFD study, and my background in engineering, mechanical engineering, CAD/CAM and finite element analysis provides a strong foundation for accurately representing the 1,600 m² level and its existing ventilation arrangement. I can support the preparation of a clear, technically organised deliverable covering the single passenger-car fire scenario, including the geometry, jet fans, extract system, inlets, smoke development, temperature, visibility, velocity fields and evacuation tenability considerations. My CAD and engineering experience is well suited to producing precise plan and section views, documenting assumptions and boundary conditions, and presenting results in a concise PDF report with suitable visual evidence. Raw model files and clearly structured documentation can also be included to support peer review and re-running. I would be pleased to apply my engineering and analysis skills to this fire-safety CFD evaluation and discuss the project scope, preferred software and required input data with you.
$266 USD in 1 day
6.6
6.6

Hi there, Hope you are doing well, I have read your job description and I understood that you are looking for mechanical engineer who can create an accurate representation of the parking-level geometry, ventilation equipment and fire-related layout. We specialize in technical drawings, structural designs, 3d modeling, mechanical designs, product designs, building designs, graphic designs, and high quality rendering. I always aim to produce high-quality outcomes that perfectly align with client expectations.I am sure that I can deliver this project on time within your budget. Please check my relevant work in my portfolio. Let's connect and discuss in brief. Thanks.
$250 USD in 3 days
6.4
6.4

Hi, I’m a Mechanical Design Engineer with years of experience in mechanical engineering, CFD/FEA analysis, CAD modeling, and engineering simulations. I’m interested in reviewing your car park ventilation system and developing a CFD study focused on smoke propagation and occupant tenability during a single passenger-car fire. My proposed approach includes: - Preparing and checking the existing 3D CAD geometry. - Modeling jet fans, extraction systems, and fresh-air inlets. - Defining the design fire, heat release rate, and fire development over the 10-minute period. - Simulating smoke propagation, temperature, airflow velocity, visibility, and smoke-layer development. - Evaluating conditions along designated escape routes against agreed tenability criteria. - Performing mesh sensitivity checks and documenting numerical convergence. - Preparing plan views, section snapshots, velocity vectors, and simulation results. - Delivering the technical report and native simulation files. A few questions before starting: 1. Do you have the existing CAD model in STEP, SAT, or another format? 2. Can you provide the jet fan specifications, fan curves, extraction rates, and inlet locations? 3. Do you have a defined design fire and heat release rate (HRR) curve? 4. Which fire-safety standards and tenability criteria must be followed? 5. Do you have the designated escape routes and occupant evacuation assumptions? Best regards,
$750 USD in 15 days
6.8
6.8

My background in architectural and commercial-space 3D modelling, drafting and design calculations can support accurate reconstruction of your 1,600 m² car-park geometry, escape routes and ventilation layout. I work with AutoCAD, Revit, SketchUp, 3ds Max and related CAD/BIM tools, allowing me to interpret drawings and produce clear plan and section documentation for technical review. I can prepare well-organised geometry, visual snapshots, rendered technical views and a concise PDF report covering assumptions, model setup, boundary information and findings. My experience with design and calculations, along with tools including Abaqus and CAD/CAM, supports careful technical documentation and presentation of simulation-related results. However, my profile does not specifically demonstrate completed fire-smoke CFD studies in ANSYS Fluent or FDS, so I would not misrepresent that experience or claim code-compliance conclusions beyond the verified analysis. I would be glad to contribute the modelling, drafting and documentation components of this project, or work alongside a fire-engineering CFD specialist to deliver a peer-reviewable result.
$251 USD in 1 day
6.0
6.0

Hello, I can perform a comprehensive CFD-based smoke movement and tenability assessment for your 1,600 m² car-park level using ANSYS Fluent or FDS. My proposed methodology includes: - Developing a 3D CFD model representing the existing jet fans, exhaust system, and fresh-air inlets. - Simulating the specified 10-minute vehicle fire scenario and smoke propagation. - Evaluating temperature, visibility, smoke-layer height, and airflow velocity along designated escape routes. - Assessing evacuation tenability against applicable fire-safety criteria. - Performing mesh sensitivity and numerical convergence checks. - Evaluating ventilation effectiveness and identifying potential smoke accumulation zones. Technical references: - SFPE Handbook of Fire Protection Engineering. - NIST Fire Dynamics Simulator (FDS) Technical Reference Guide. - Relevant NFPA 92 smoke-control engineering principles. Deliverables: A technical PDF report, CFD contour plots, velocity vectors, mesh sensitivity results, and the simulation files for independent review. To establish reliable boundary conditions, I would need the architectural drawings, ventilation layout, jet fan specifications, exhaust fan curves, and design fire parameters. I would be pleased to review your available technical documentation and establish the simulation methodology. Best regards, Structural & CFD Simulation Engineer
$250 USD in 3 days
5.6
5.6

Hello, At Vutuk Design and Media, our thermal-fluids and engineering simulation team specializes in CFD smoke extraction modeling, life safety ventilation studies, and advanced numerical analysis. Backed by 15 years of industry experience across ANSYS Fluent and CAD/CFD workflows, we deliver accurate airflow and smoke clearance predictions for complex facilities. Before we establish the primary CFD domain mesh, boundary conditions, and solver setup for your smoke clearance evaluation, please consider: Are there specific fire safety codes (e.g., NFPA, EN, or local building regulations) that define the required smoke-free height and time limits? Will you require comparative simulations evaluating natural ventilation versus forced mechanical smoke extraction fan configurations? Would you benefit from photorealistic 3D airflow renderings and animated smoke clearance clips for presentations to stakeholders? What preferred report formats (e.g., PDF summary tables, contour plots, CSV data exports) are needed for your project documentation? Beyond CFD smoke simulation, we offer structural FEA analysis, 3D CAD modeling, and high-resolution visual presentation services. We invite you to visit our profile and portfolio to inspect our previous engineering simulation and fluid mechanics work. Let's make your project a success. Best regards, Vutuk Design and Media
$500 USD in 7 days
5.4
5.4

My CAD/CAM and Mechanical Engineering skills provide a technical foundation for working with engineering drawings and structured technical documentation. I also hold a degree in Business Administration and bring 13 years of experience in organised, detail-focused operational work, including reporting, inventory control and compliance with defined standards. For your CFD smoke-clearance evaluation, I can contribute to the preparation and organisation of the technical documentation, drawings, model records and report materials required for review. I want to be transparent that my profile does not demonstrate prior experience running ANSYS Fluent, FDS or fire-safety CFD simulations, so I cannot responsibly claim expertise in mesh sensitivity, smoke tenability, critical velocity or code-based validation. I would be glad to support the project where my CAD/CAM, engineering and documentation skills are appropriate, while the CFD analysis and life-safety conclusions should be handled by a demonstrated fire-engineering CFD specialist.
$500 USD in 7 days
5.3
5.3

Hello, I can assist with preparing your existing 1,600 m² car-park model for a detailed smoke-clearance CFD study using ANSYS Fluent or another suitable fire-simulation platform. The analysis should reproduce the existing jet fans, extract system, and air inlets, while evaluating smoke spread, layer height, temperature, visibility, and airflow along designated escape routes during the 10-minute fire scenario. I can help prepare the geometry, organize the simulation inputs, and develop clear plan and section visualizations showing smoke development and velocity patterns. The study should include documented boundary conditions, mesh sensitivity checks, convergence evidence, and raw model files for independent review. Final tenability conclusions and life-safety recommendations should be verified by a qualified fire-safety engineer against the applicable codes. Please share the CAD drawings, ventilation layout, fan curves, design fire specifications, and escape-route information so the scope and turnaround can be assessed accurately.
$250 USD in 7 days
5.3
5.3

Hi, I can help with the CFD fire and smoke analysis of your 1600 m² car park using ANSYS Fluent or FDS. I will assess smoke spread, temperature, visibility, and evacuation safety under the 10-minute design fire scenario. I can provide a detailed report, simulation snapshots, mesh sensitivity analysis, and raw model files for review. Please share the CAD drawings, ventilation details, fan curves, and fire scenario specifications so I can review the scope and estimate the timeline. Looking forward to working with you!
$500 USD in 7 days
5.0
5.0

Hi there, I'm a senior mechanical engineer with extensive experience in machine and product design. You can see my portfolio. I'm ready to help you make: ✨ A detailed PDF report summarising assumptions, mesh sensitivity checks, and tenability results. ✨ Plan and section snapshots showing smoke layer height, visibility, and velocity vectors. ✨ Screen-capture evidence confirming model convergence and adherence to current fire-safety codes. ✨ Fully documented raw CFD model files and clear conclusions on evacuation safety. I'm excited to work with you on your project and deliver the best results possible. I'm waiting for your message.
$375 USD in 1 day
4.4
4.4

I am a Mechanical/Mechatronics Engineering researcher with extensive experience in CFD simulations, fluid flow analysis, and heat transfer modeling using ANSYS Fluent and COMSOL. I can develop a detailed CFD model of the 1600 m² car-park level to investigate fire-induced smoke propagation, temperature distribution, airflow patterns, and ventilation performance. The study will incorporate the existing jet fans, exhaust systems, air inlets, fire source characteristics, and appropriate boundary conditions. I can evaluate smoke layer development, visibility, temperature, airflow velocity, and evacuation-route tenability over the specified 10-minute fire scenario. Mesh independence and numerical sensitivity studies will be performed to establish the reliability of the simulation results. Deliverables will include the simulation files, visualizations, and a comprehensive technical report documenting the methodology, assumptions, results, and ventilation improvement recommendations. I would be happy to discuss the available drawings, fan specifications, fire scenario, and applicable safety standards before commencing the project.
$500 USD in 7 days
4.2
4.2

⚡ YOUR CFD STUDY NEEDS TO ENSURE SAFE EVACUATION. We specialize in detailed CFD evaluations for fire safety, with extensive experience using ANSYS Fluent and FDS. Our team has tackled similar projects, focusing on smoke management and evacuation strategies in complex environments. What you truly need is a comprehensive analysis that guarantees occupant safety during a fire event, meeting all relevant fire-safety codes. We will replicate the existing ventilation setup, conduct a mesh sensitivity check, and document boundary conditions. Additionally, we’ll provide clear evidence of model convergence to support our findings. I will personally oversee the project, ensuring smooth communication and thorough review of all deliverables before you receive them. MESSAGE ME, LET'S SEE IF WE'RE A GOOD FIT. Regards, Stefan Clavorn Collective
$400 USD in 14 days
3.9
3.9

I understand you require a robust CFD analysis to demonstrate safe evacuation from a car-park level during a single passenger-car fire, similar to projects where I've successfully modeled fire and smoke dynamics to validate evacuation strategies and ventilation system performance. My approach centers on creating a high-fidelity model that accurately reflects your specified 1600m² car-park geometry and existing ventilation infrastructure, including jet fans, extract systems, and inlets. I will utilize ANSYS Fluent for the CFD simulations, employing a k-epsilon turbulence model and a transient solver to capture the evolving fire and smoke plume. The simulation will run for a 10-minute design fire scenario, tracking key metrics like smoke spread, layer height, temperature, and visibility along the designated escape routes, with a focus on achieving a minimum visibility threshold for life safety. My methodology involves discretizing the car-park into a suitable mesh resolution to ensure accurate capture of flow phenomena, particularly around the fire source and ventilation outlets. I will implement a fire source model that simulates the heat release rate and smoke production of a single passenger-car fire. Post-processing will involve extracting detailed data for smoke clearance times, calculating critical velocities at key locations, and generating clear visualizations of tenability limits and visibility contours. This will provide you with the quantitative evidence needed to validate the safety of the evacuation route. To ensure alignment with your specific requirements, could you clarify the exact location and flow rate of the extract system and inlets? Additionally, what specific visibility criteria (e.g., meters) are being used to define safe evacuation? I'm confident my expertise in CFD fire and smoke modeling can deliver the detailed, actionable insights you need. I'm available to discuss this further at your earliest convenience.
$534 USD in 21 days
3.5
3.5

Hello, I am a CFD Engineer with experience in various types of fluid flow and thermal simulations, proficient in ANSYS Fluent, STAR-CCM+, and OpenFOAM. I am very interested in your project and would be happy to collaborate with you to deliver a high-fidelity CFD simulation, supported by a well-documented methodology and reliable numerical results. I look forward to discussing the project further. Regards, Walid
$500 USD in 7 days
3.1
3.1

Hi there, Thank you for sharing the project requirements. I understand that this is a fire-safety-critical CFD study, where accurate modelling and properly documented results are essential. I have experience with 3D modelling, technical visualisation, and mechanical design. However, I would not want to misrepresent my experience by claiming specialist fire-engineering CFD expertise or the ability to certify evacuation safety. This project requires a qualified fire-safety/CFD engineer experienced in FDS or ANSYS Fluent, including fire modelling, tenability analysis, mesh sensitivity studies, and applicable fire codes. I can potentially assist with 3D model preparation, technical visualisation, and report graphics if you have a CFD specialist handling the simulations and engineering conclusions. Best regards, Nadarajan Kiruba
$250 USD in 2 days
2.6
2.6

CFD and engineering analysis are central to my work, with experience preparing analysis reports using ANSYS, COMSOL, ABAQUS, NX and Siemens STAR software. That makes me well suited to evaluate your 1,600 m² car-park level, including the ventilation arrangement, fire-driven smoke movement and the engineering evidence needed for review. My Computational Fluid Dynamics, mechanical engineering and FEA background supports a technically documented assessment of smoke spread, temperatures, visibility, smoke-layer development, velocity fields and evacuation tenability. I can also provide clear plan and section visualisations, report the mesh and boundary-condition assumptions, and include raw model files and convergence evidence for peer review. The final conclusions can directly address smoke-clearance performance, critical velocity and any ventilation recommendations. I would be pleased to carry out the study using a recognised ANSYS-based CFD workflow, subject to the available project data, and deliver a concise, professional report with the requested supporting outputs. Choose me for a focused CFD and engineering assessment of your car-park fire scenario.
$250 USD in 7 days
2.2
2.2

Hi, I can help with your CFD smoke clearance evaluation for the car-park fire scenario. I have strong experience in CFD, mechanical engineering, and fire-related flow modeling, and I can document a clear, code-aligned methodology using ANSYS Fluent, FDS, or another suitable solver. I will assess smoke spread, layer height, temperature, visibility, tenability, and evacuation conditions for the single-level 1600m² parking area, while keeping the scope limited to the specified level only. I can also include mesh sensitivity, boundary condition justification, convergence evidence, and annotated snapshots for review. https://www.freelancer.com/u/QuickMentor If you share the available drawings, fan curves, and any ventilation details, I can review the setup and discuss the best approach for your study. Thanks, Abdur Rehman
$250 USD in 7 days
2.2
2.2

Smoke clearance evaluation for the 1600m2 car-park level will be modelled in FDS, the free NIST fire-dynamics solver, replicating the existing jet fans, extract points and inlets. This price covers the first milestone: FDS geometry and ventilation set-up, mesh sensitivity check, the 10-minute design fire run, and a PDF report with plan/section snapshots of smoke layer height, visibility, temperature and critical velocity along escape routes, plus screen-capture convergence evidence and raw model files. Peer-review access included; the whole-building sign-off for code submission to your authority remains with your licensed fire engineer. Further floors or design-fire variants would be a next milestone. Please send the ventilation drawings, fan curves and floor plan to start. Price: 375 USD fixed · Timeline: 8 working days from access/brief Konrad
$375 USD in 8 days
1.6
1.6

Hello There, I read your project description carefully and understand your requirements. As an Engineer with experience in CFD simulations using ANSYS Fluent, I can perform the smoke clearance evaluation, including smoke propagation analysis, visibility assessment, temperature distribution, tenability checks, mesh sensitivity study, and ventilation performance evaluation. The final deliverables will include the CFD model, supporting report, convergence verification, result visualizations, and recommendations based on the simulation findings. I invite you to kindly visit my profile and portfolio for similar engineering projects. I would be happy to discuss the project requirements in more detail. Thank you for your time and consideration. With Regards, Diptesh.
$650 USD in 15 days
0.0
0.0

Izmir, Turkey
Member since Nov 3, 2026
$100-10000 USD
$250-750 USD
₹12500-37500 INR
$250-750 USD
₹12500-37500 INR
₹12500-37500 INR
$250-750 USD
$15-25 USD / hour
$8-15 USD / hour
$750-1500 USD
₹12500-37500 INR
£20-50 GBP
₹12500-37500 INR
₹12500-37500 INR
€30-250 EUR
$10-30 USD
$30-250 USD
$250-750 USD
$750-1500 USD
$250-750 USD
₹12500-37500 INR
$25-50 USD / hour