
In Progress
Posted
Paid on delivery
I have two detailed SolidWorks maxilla models—each containing a dental implant in the canine region (one 4.1 mm, one 3.3 mm). Before I can trust any results, the files need to be made fully FEA-ready: clean up the complex anatomical surfaces, repair the current mesh issues, and confirm every small detail is watertight so ANSYS does not complain. Once the geometry is sound, move the workflow into ANSYS. The meshing step must balance both refinement around the implant–bone interface and overall element quality; that dual focus is essential for the occlusal loading I will apply. After meshing, set up a static structural analysis that includes: • A 35 N·cm screw-torque preload on the designated model • Physiologic occlusal forces on both implants • Appropriate contacts and boundary conditions representing cortical and cancellous bone Deliverables I expect: 1. Corrected SolidWorks assemblies (native and STEP) with a short changelog of the fixes you made 2. ANSYS project file with final mesh, boundary conditions, and solver settings 3. A concise report (figures plus brief commentary) showing displacement, von Mises stress, and implant–bone interface stresses for each model Experience with dental or orthopedic biomechanics is a hard requirement; general mechanical FEA alone won’t be sufficient. If you have handled bone–implant simulations before, this should be straightforward and fast.
Project ID: 40591254
20 proposals
Remote project
Active 3 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
20 freelancers are bidding on average $555 USD for this job

As biomedical engineers with a specialization in mechanical design and an extensive background in CAD, my team at MHTechFusion is uniquely qualified to meet your requirements for this project. Our comprehensive understanding of complex anatomical surfaces and iterative meshing enables us to not only clean up the existing files for FEA analysis but also ensure that they're watertight and ready for ANSYS. With our meticulous approach and broad experience in mechanical simulations, we can seamlessly navigate the dual challenge of precise mesh refinement around the implant-bone interface while maintaining overall element quality. Your project demands more than just mechanical FEA know-how; it requires domain expertise in dental or orthopedic biomechanics—something we possess. We've successfully dealt with numerous bone-implant simulations before and are familiar with the nuances it entails. Being adept at delivering precise, concise reports with meaningful insights, you can expect accurate documentation showcasing displacement, von Mises stress, and implant-bone interface stresses for each model. Our commitment to not only meeting but exceeding client expectations sets us apart. By selecting us for this project, you can trust that you'll receive fully corrected SolidWorks assemblies (native and STEP) alongside an ANSYS project file that encapsulates the final mesh, boundary conditions, and solver settings.
$750 USD in 7 days
7.0
7.0

With over 10 years in the industry and a deep understanding of CAD mechanics, I'm confident I can execute this project to your utmost satisfaction. My skill set is not limited to general mechanical FEA but extends precisely towards dental and orthopedic biomechanics, making me uniquely qualified for this task. Pitch: I have handled several bone-implant simulations before, which dismantles complex anatomical structures into FEA-ready geometry. My focus on clarity, durability, and accurate detailing ensures each aspect of your SolidWorks files are perfectly refined for seamless ANSYS transition. This eliminates the chances of an ANSYS complaint through watertight planning and meshing strategies. The deliverables you're expecting align with the nature of my work: precise geometry, clean detailing, and production ready files. I assure you native and STEP file formats with a comprehensive list of all the issues resolved. Further, I will submit an ANSYS project file with final mesh, boundary conditions, solver settings alongside concise reports showing displacement, von Mises stress, and implant-bone interface stresses. In choosing me for this project, you'll not only get expertise in dental implant FEA analysis but also transparent communication, professional trust and client satisfaction. Your project will receive my diligent attention to guarantee polished results tailored precisely to your requirements
$255 USD in 2 days
6.4
6.4

Hi, I am pleased to submit my proposal for your dental implant FEA project. I have experience with SolidWorks, ANSYS Mechanical, nonlinear contact analysis, and biomechanical simulations, and I understand the importance of preparing anatomically complex CAD models for reliable finite element analysis. My workflow begins by repairing and simplifying the SolidWorks geometry, eliminating gaps, overlapping faces, sliver surfaces, and mesh defects to create watertight, analysis-ready models. I will then generate a high-quality ANSYS mesh with local refinement at the implant–bone interface while maintaining excellent overall element quality and convergence. The analysis setup will include: 35 N·cm implant screw preload (where required) Physiological occlusal loading on both implant models Appropriate bonded/frictional contacts Cortical and cancellous bone material assignments Realistic boundary conditions and mesh convergence verification Deliverables: Corrected native SolidWorks and STEP files with a geometry change log Complete ANSYS Workbench project High-quality mesh, contacts, loads, and solver settings Best regards,
$1,500 USD in 25 days
6.5
6.5

I am excited to apply for your Dental Implant FEA Analysis project. I have experience in finite element analysis, biomechanical simulation, and engineering evaluation of dental implant systems to assess stress distribution, deformation, and overall structural performance. I can help analyze implant designs by creating accurate 3D models, defining material properties, applying realistic loading conditions, and delivering reliable simulation results to support design optimization. My expertise includes working with FEA tools such as ANSYS, Abaqus, COMSOL, and similar simulation platforms to evaluate implant components, bone-implant interactions, and mechanical behavior under different forces. I can perform mesh generation, boundary condition setup, stress and strain analysis, and interpretation of simulation data while considering relevant biomechanical factors. My approach focuses on accuracy, scientific methodology, and clear reporting of findings for research, development, or clinical applications. I am committed to providing high-quality engineering analysis, detailed documentation, and timely project delivery. I would be glad to discuss your implant design requirements, material specifications, loading scenarios, and desired outcomes to develop a comprehensive FEA study that provides valuable insights into the performance and reliability of your dental implant system.
$250 USD in 7 days
5.0
5.0

As a seasoned 3D designer with an emphasis on mechanical design and engineering tasks, I possess an enviable proficiency in SolidWorks and CAD/CAM expertise. Moreover, I'm well-versed with the intricacies of bone-implant simulations, having previously delivered successful projects in dental and orthopaedic biomechanics. My comprehensive understanding of FEA not only ensures meticulous meshing techniques that balance implant-bone interfaces but also guarantees that crucial properties like structural displacement and von Mises stress are accurately captured and analysed. The ability to troubleshoot and efficiently deal with complex anatomical surfaces is another strength I bring to the table. Before employing the files for analysis, I'll diligently ensure they are FEA ready by cleaning up the meshing issues and verifying the watertightness of all components using ANSYS. At each step, I'll document the fixes made ensuring easy reference in case any concerns arise. In conclusion, engaging me for your Dental Implant FEA Analysis project assures you of not only fastidious engineering skills developed over the years but also an orientation towards delivering high-quality work that exceeds client expectations, on time and within budget. Looking forward to harnessing this opportunity to exhibit my dexterity in bone-implant simulations while helping you generate invaluable insights from your individual dental implants.
$500 USD in 2 days
4.0
4.0

Riyadh, Saudi Arabia
Payment method verified
Member since Jun 15, 2025
$250-750 USD
$750-1500 USD
$8-15 USD / hour
₹100-400 INR / hour
₹75000-150000 INR
₹1500-12500 INR
₹750-1250 INR / hour
$10-20 AUD
$30-250 USD
₹12500-37500 INR
$750-1500 AUD
$250-750 USD
$30-250 AUD
$250-750 AUD
₹600-1500 INR
$250-750 USD
$250-750 USD
$250-750 USD
$14-100 NZD
₹240000-280000 INR
₹37500-75000 INR